Reference MIL-STD-202
Method 305:
Test Frequency: 1000Hz
Temperature: +25°C
Capacitance
Change -vs -Temperature
Acceptance Limits:
@ -55°C
= +2% Maximum Change
@ +25°C
= ±0.10%
Maximum Change
@ +105°C
= -2.5% Maximum Change
Reference MIL-STD-202
Method 306:
Test Frequency: 1000Hz
Temperature: +25°C
Acceptance Limit: .10%
Maximum
Reference MIL-STD-202
Method 302:
Electrification shall
be at rated voltage or
500VDC, whichever is
less and for a time
not greater than 2
minutes.
Test Megohms
X mf Megohms Temperature Minimum Need
not exceed @ +25°C 100,000 200,000 @ +85°C 5,000 20,000 @ +105°C 1,000 5,000
Reference
MIL-PRF-19978F
Acceptance
Limit: .03%
100%
of listed voltage rating from -55°c to +105°C
Reference
MIL-STD-202 Method 301: Surge current is limited to 1 ampere maximum. Voltage
applied for 1
minute
(maximum) @ 25°C.
Ground test is performed terminal to case (where the case is not a terminal)
at
200% of the DC voltage rating. Dielectric strength test is performed terminal
to terminal at 150% of the
DC
voltage rating.